The Control Unit verifies that no other zone exists in the system with
that identification. If it does not already exist, the identification is
validated and normal operation begins
If the zone identification has already been assigned to another
Control Unit, the installer will be prompted to key in another
identification. The Control Unit will not operate until a valid zone
identification is entered
To do this, key in the identification to be assigned and press the PRG
key. For example, in order to assign zone 28.
The first time power is fed to a Control Unit it must be installed. The first step (required to
continue) is to program its identification.
A Control Unit is identified by:
)
)
)
an individual zone identification (installation menu)
a group identification (installation menu)
a name (program menu)
By default, the Control Unit settings are stereo and 16 ohms speaker.
Other settings can be defined in the installation menu options 4.1.6 , 4.1.8
The power supply for any Control Unit is controlled from the Master Unit
414A1/A2. See 3.1.1.A. Manual System Off/On
Once the Control Unit has been installed it is ready for normal operation.
To know the zone identification, group and name:
Key Sequence Display Visual
PRG
8
tuv
2
abc
ADDRSS 28
x 28
ADDRSS 1
28
rosa ADDRESS 40
grOUP 2
PRG
0
C
A zone identification number must be defined prior to enabling the control unit's
normal operation mode. The number must be between 1 and 250 and be
different for each of the control units of the same installation.
36
422A1/A2
42991
428A1
4.1.1. The First Time...
CC-1023ENG-10